Vented or Sealed: Choosing a Crawl Space Design in SeaTac

Washington's code allows two ways to build a crawl space: keep it vented to the outdoors with a ground cover, or seal it and manage the air. Both can work in SeaTac. This guide explains what each requires and how to tell which suits a particular house.

Vented vs sealed crawl space: two designs, one goal

Every crawl space design is trying to keep the wood framing and the floor above it dry. They take opposite routes.

  • Vented. Outdoor air moves through screened openings in the foundation wall, carrying away moisture, while a plastic cover keeps the soil's moisture down.
  • Sealed (unvented). The vents are closed, the soil and walls are lined with a sealed vapor retarder, and a continuously running exhaust fan carries crawl space air outside. This is what most contractors mean by encapsulation.

Neither is automatically better. The right answer depends on what is under the house, what water reaches it, and how the house above behaves.

What the state code asks of a vented crawl space

Washington sets its crawl space rules in its own amendment of the national residential code, WAC 51-51-0408. For a vented space, it requires:

ElementRequirement under WAC 51-51-0408
Ground coverSix-mil black polyethylene or an approved equal over the soil, overlapped 6 inches, extended to the foundation wall
Vent areaAt least 1 square foot of net vent for every 300 square feet of crawl space
Vent screensOpenings no larger than a quarter inch
Reduced ventingVent area may drop to 1 in 1,500 when a Class I vapor retarder covers the ground; a radon vent is required if venting falls below 1 in 300 or operable louvers are installed

The quarter-inch screen does two jobs. It keeps vents open for air, and it matches the Washington State Department of Health's guidance that openings over a quarter inch let mice in.

A vented design is cheaper to build and simpler to maintain. Its weak point is the cover: if the plastic is torn, partial or buried, ground moisture comes straight up, and the vents cannot keep pace through a wet winter.

What the state code asks of a sealed crawl space

Washington amended the national rule (IRC R408.3), and the unvented path in the same WAC 51-51-0408 is stricter. It lists two numbered items under which vent openings are not required:

  1. A continuous Class I vapor retarder over the exposed earth, with joints overlapped 6 inches and sealed or taped, and edges carried 6 inches up the stem wall, attached and sealed there, together with a radon system built to Appendix AF.
  2. Continuously operated mechanical exhaust at 1 cfm for every 50 square feet of crawl space floor, discharging outside.

The state's version drops the national text's alternative to that exhaust fan. A dehumidifier can be added, but it never replaces the exhaust fan. No connecting word sits between items 1 and 2, so the City of SeaTac building official confirms how they apply to your address before the vents are closed.

In practice a sealed design usually brings a heavier liner, attention to every penetration where pipes and posts go through the liner, a radon pipe or provision, and, where the design uses item 2, a small exhaust fan on its own circuit. Under the City of SeaTac's permit types page, adding a circuit to existing wiring needs an electrical permit, so the fan is usually a permit item.

Once the space is sealed, the energy code's R-30 floor insulation still applies unless the design moves the insulation to the walls, which is a decision for the plan, not an afterthought.

What federal research found in this climate

Crawl space marketing often borrows results from the Southeast. The U.S. Department of Energy's Building America research profile on unvented crawl spaces reports a North Carolina study where vented crawl spaces stayed above 70 percent humidity in warm months and closed ones cut heating and cooling energy by 15 to 18 percent.

The same profile reports a different picture for the Pacific Northwest's marine climate: vented and closed crawl spaces both performed adequately, as long as the ducts were not in the crawl space. That is the most useful single finding for a SeaTac owner. Sealing is not required to have a dry crawl space here, but it earns its keep when ducts or equipment live under the floor.

Ducts, furnaces and water heaters under the floor

Many SeaTac houses from the 1960s and 70s put the furnace, the ducts or the water heater in the crawl space. Ducts in a vented space sit in cold, damp outdoor air all winter. Any leak at a joint pulls that air into the system, and the duct surfaces lose heat to the space.

That is exactly the case the DOE profile carves out. With ducts below the floor, a sealed design brings them inside a drier, more stable space. Without them, a well-covered vented space usually performs as well.

A gas furnace or water heater in a sealed space also needs its combustion air and venting checked, because closing the foundation vents changes the air around the appliance. That belongs in the plan before the vents are closed.

Tight houses and the Port's sound insulation

The Port of Seattle's Sound Insulation Program has insulated more than 9,400 single-family homes near the airport in a program that began in 1985, typically homes built before 1986 or 1987 inside the noise remedy boundary. The page does not itemize the home work beyond a homeowner's mention of "new windows and insulation", and it says nothing about crawl spaces or floors, so it gives no basis for assuming the program changed anything below the house.

What it does change is how tight the house is. A home that leaks less air also lets less moisture out, so the house becomes more sensitive to moisture from below. The EPA's moisture guidance sets indoor humidity below 60 percent, ideally 30 to 50 percent. In a tightened house, a vented crawl space with a poor cover is the first thing to fix. Whether to go further and seal it follows the same logic as any house: ducts below, persistent damp air or a musty smell point toward sealing; dry framing and a sound cover point toward keeping it vented. The humidity post covers this in more depth.

Radon and the sealed path

Radon is a soil gas, and the crawl space is where it meets the house. The EPA calls it the second leading cause of lung cancer and the leading cause among people who have never smoked. King County is in the EPA's lowest radon zone, but the EPA's Washington map still says all homes should be tested.

The code ties radon to the design. A vented space that reduces its vents on the strength of a Class I retarder needs a radon vent; a sealed space needs a radon system (WAC 51-51-0408), and the City of SeaTac building official confirms which applies to the house. The Building America Solution Center, whose content Pacific Northwest National Laboratory provides for the U.S. Department of Energy, calls for a radon test kit to be given to the homeowner at completion in its checklist for converting a vented crawl space to unvented. The EPA's radon reduction guide names sub-membrane suction, which uses the liner itself, as the most effective method for crawl space homes. A sealed liner laid with a radon pipe in place makes that easy to add if a test calls for it.

Water decides first

Neither design survives standing water. NOAA's normals for Sea-Tac Airport put annual precipitation at 39.34 inches, mostly from October through March, and the state's geologic map viewer shows dense Vashon till across much of the plateau. On till, winter water can pond under a house.

If an inspection finds water, drainage comes before any decision about vents. A sealed liner over a wet floor traps the water against the soil; a vented cover floats. The drainage page explains how to tell rain water from a plumbing leak, and the post on SeaTac glacial till explains why the plateau holds water.

Winter vents and frozen pipes

A vented crawl space brings outdoor air past the pipes. Seattle Public Utilities doesn't serve SeaTac, but its regional frozen-pipe advice says pipes exposed to drafts from open foundation vents are the most likely to freeze, and suggests blocking vents temporarily in a cold snap and reopening them in spring to prevent dry rot. A sealed space removes that drill, at the cost of mechanical exhaust that has to keep running.

Rentals: which design is easier to own?

More than half of SeaTac's occupied homes are rented, according to American Community Survey figures on Census Reporter. For a landlord, the design question has an extra side: who will keep it working?

  • A vented space with a good cover has nothing to switch on. It needs a look at each turnover for torn plastic and damaged screens.
  • A sealed space depends on an exhaust fan, and sometimes a dehumidifier, running all year. A tenant may unplug it, or a breaker may trip, and nobody notices for months.

Washington's RCW 59.18.060 requires landlords to keep a rental weathertight and fit to live in. Either design can meet that, but a sealed space in a rental needs a maintenance plan: a labeled switch, a check at each turnover, and a note in the tenant information.

A decision table for SeaTac houses

What the inspection showsLeans towardWhy
Dry framing, no ducts below, cover tornVented with a new coverThe DOE found vented spaces adequate here without ducts below
Ducts or furnace in the crawl spaceSealedBrings the ducts inside a drier space
Musty smell upstairs and damp air even with a good coverSealedThe air needs control, not just the soil
Water pooling after stormsDrainage first, then decideNo design works over standing water
Rental with no reliable way to check equipmentVented, or sealed with a maintenance planSealed spaces depend on a fan running
Low clearance and many penetrationsOften vented with a heavy coverSealing every pier and pipe adds cost

The encapsulation page and the vapor barrier page describe each option's install, and the cost guide compares their prices.

Get referred to a local pro

Questions to put to a contractor proposing either design

  1. Which path in WAC 51-51-0408 is this design: vented, reduced-vent with a Class I retarder, or unvented?
  2. Where are the ducts, and how does the design treat them?
  3. What happens to any water first?
  4. What radon provision is included, and will a test follow?
  5. For a sealed space, what runs continuously, on which circuit, and with what permit?
  6. Who checks it after the job, and how will I know it's working?

Check registration on L&I Verify; Washington's RCW 18.27.100 requires the number in the contractor's advertising.

Frequently asked questions

Is a sealed crawl space required in SeaTac?

A sealed crawl space is not required: Washington's WAC 51-51-0408 allows a vented crawl space with a proper ground cover and screened vents, or an unvented one built to its sealed rules, as the City of SeaTac building official confirms for the address. The choice depends on water, ducts and the air under the house.

Does closing my vents make my crawl space sealed?

Closing the vents alone does not create a sealed crawl space under Washington's code, and it can make a damp space worse. On a SeaTac rambler, shutting the vents with nothing else changed simply traps damp till air under the floor. The state's unvented path is a written design with its own numbered items: the first, a sealed liner paired with radon piping; the second, a fan exhausting outdoors. The City of SeaTac building official decides how they apply to the house.

Will sealing a crawl space lower my heating bill in this climate?

Sealing may lower heating costs mainly when ducts run through the crawl space. The DOE's Building America profile found vented and closed crawl spaces both performed adequately in the Pacific Northwest marine climate when ducts were not in the crawl space.

Is a vented crawl space safe from radon?

A vented crawl space dilutes soil gas but cannot promise a low reading, so a radon test is still the way to know. The EPA says every Washington home should be tested regardless of zone, and the state code adds radon provisions when vents are reduced or removed, as the City of SeaTac building official confirms for each design.

Can an older SeaTac house be converted from vented to sealed?

An older house can usually be converted, provided water is dealt with first and the furnace or water heater combustion air is checked. The Building America Solution Center's checklist for converting a vented crawl space to unvented calls for a radon test kit to be handed to the homeowner at completion.

Which design is easier for a landlord to maintain?

A vented crawl space with a sound cover is usually easier for a landlord, because nothing in it needs power. A sealed space works well in a rental too, but its exhaust fan must keep running, so it needs a labeled switch and a check at each tenant turnover.